Low-Voltage Data Acquisition

From bildr

Jump to: navigation, search

Data acquisition and control systems need to get real-world signals into the computer. These signals come from a diverse range of instruments and sensors, and each type of signal needs special consideration.

Thermocouples provide a low-voltage signal, typically a few millivolts. The relationship between temperature and voltage is non-linear. The voltage depends on:

  1. The temperature difference between the thermocouple junction itself and the point where the thermocouple wires terminate - the cold junction.
  2. The temperature of the cold junction.

Temperature measurement systems using thermocouples need to provide a means of measuring the cold junction temperature (often using a platinum resistance device) and an algorithm for linearising the voltage readings to temperature. Microlink hardware runs the Interface Management Language (IML) whose linearisation functions currently support B, E, J, K, N, R, S and T type thermocouples.

This page is an Article on bildr. Articles are pages that define or explain a concept, method, or generic item.

NOTE: All information contained within this article is pure opinion. Although this article is intended to help people, it may contain faulty or misleading information. This article is not to be considered professional opinion or advice, and is in no way a replacement for reading all safety/instructional documentation. Always remember to protect yourself when handling/using hazardous materials, as well as test new techniques before using them on projects/work intended to be handed in or used.